Options: heat quantity measurement, liquid
sound velocity measurement

Dual Channel Portable
Ultrasonic Flowmeter
|
|
The non-invasive
flowmeters utilizes ultrasonic technology for the accurate flow
measurement of liquids in full pipes. The measurement of flow is based
on the principle that sound waves traveling in the direction of flow
of the fluid require less time than when traveling in the opposite
direction. The difference in transit times of the ultrasonic signals
is an indication for the flow rate of the fluid. In those rare cases
where the amount of gaseous or solid content in the liquid becomes too
high for the transit-time mode to operate, the unit can revert to the
Doppler - NoiseTrek™ mode,
which relies on particles or gas bubbles flowing with the liquid. For
further information on the measuring principle, please
click here.
|
Easy
to use
The ultrasonic sensors are clamped onto the outside of the pipe,
thus eliminating the need to dismantle the pipe work and interrupt
the process. An ultrasonic flowmeter can be applied to any type of
standard pipe carrying clean or dirty liquids. The set-up of the
unit is simple through an interactive dialogue. Diameter,
thickness and material of the pipe and the fluid to be measured
need to be entered via the keypad. With the clamp-on sensors
positioned correctly, the flow rate of the liquid can be
determined in minutes.
|
|
Intelligent sensors
The calibrated sensors have automatic parameter transfer to the
portable unit, which facilitates easy operation avoiding
installation errors. As a result, the flowmeter provides accurate
measurements without the necessity of a zeroing or extensive
learning procedure. Watertight sensors and integrated robust
sensor cables make it possible to obtain measurements over a long
period of extensive usage.
|
|
Integrated
data logger Without a
strip-chart recorder or control system connected, all data is
securely captured in the unit. An internal data logger is standard
and includes the necessary transmission and evaluation software.
With this software, the data can be collected, visualized and
printed out, or the measurements converted for further evaluation
through standard PC programs. Should there be no PC available, the
data can also be transferred directly to a printer.
|
Heat quantity
measurement (HQM)
With the integrated heat quantity measurement option, it is
additionally possible to measure the flow of thermal energy. The heat
quantity coefficients for various media are already pre-programmed.
Pipe wall
thickness measurement (WTM) In certain
applications, the pipe wall thickness is not always a known quantity.
As the wall thickness is a critical parameter for clamp-on flow
measurements, the portable unit can be supplied with an optional wall
thickness gauge.
Applications
- Distribution and consumption measurements
- Leak detection
- Inspection of fixed installation flowmeters
- Measurement of aggressive media
- Monitoring of coolant and heating circuits
- Plant start-up and commissioning
- Pump inspection
- Hygienic flow measurements
- CIP flow and process monitoring
- Survey work
- System balancing
|
|
Download