bannerright

Flowmeter-clamp-on-2

Technical Inquiries

support-form3

Field Mounted Ultrasonic Flowmeters

 

Low Cost Field Mounted Ultrasonic Flowmeter
KATflow 100

KF100 small

 

  • Transit-time correlation measurement
  • Wall mounted unit with or without display
  • One measurement channel
  • Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
  • Resolution: 0.25 mm/s (0.05 ft/min)
  • Repeatability: 0.15% of measured value ± 0.015 m/s (2.95 ft/min)
  • Accuracy: Flow velocity: ± 0.5% of measured value Volume flow: ± 1 to 3% of measured value depending on application
  • Turn down ratio: 1 / 100
  • Serial interface RS 232; RS 485 OR Modbus RTU optional
  • Outputs: current (HART), voltage and digital (pulse / relay)
  • Non-invasive: no pipeline disturbance or pressure loss
  • Easy to install clamp-on sensors with no process interruption
  • All commonly used pipe materials, pipe diameters 3/8" to 118"

 

Multifunctional Field Mounted Ultrasonic Flowmeter
KATflow 150

KF150 small

 

  • Transit-time correlation measurement
  • Dual DSP-technology for better measurement accuracy
  • Wall mounted unit with graphic display
  • One or two channels
  • Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
  • Resolution: 0.25 mm/s (0.05 ft/min)
  • Repeatability: 0.15% of measured value ± 0.015 m/s (2.95 ft/min)
  • Accuracy: Flow velocity: ± 0.5% of measured value Volume flow: ± 1 to 3% of measured value depending on application
  • Turn down ratio: 1 / 100
  • Serial interface RS 232; RS 485 or Modbus RTU optional
  • Data logger for up to 30,000 samples (optional > 100,000 samples)
  • Outputs: current (HART), voltage and digital (pulse / relay)
  • Input: current / 4 - wire Pt100 Temperature for energy measurement
  • Non-invasive: no pipeline disturbance or pressure loss
  • Easy to install clamp-on sensors with no process interruption
  • All commonly used pipe materials, pipe diameters 3/8" to 118"

ATEX Field Mounted Ultrasonic Flowmeter
KATflow 170

KF170 small

 

  • Explosion-proof field housing, pipe mounted, ATEX II 2G Ex de IIB T6
  • Transit-time correlation measurement
  • Dual DSP-technology for better measurement accuracy
  • Wall mounted unit with graphic display
  • One or two channels
  • Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
  • Resolution: 0.25 mm/s (0.05 ft/min)
  • Repeatability: 0.15% of measured value ± 0.015 m/s (2.95 ft/min)
  • Accuracy: Flow velocity: ± 0.5% of measured value Volume flow: ± 1 to 3% of measured value depending on application
  • Turn down ratio: 1 / 100
  • Serial interface RS 232; RS 485 or Modbus RTU optional
  • Data logger for up to 30,000 samples (optional > 100,000 samples)
  • Outputs: current (HART), voltage and digital (pulse / relay)
  • Input: current / 4 - wire Pt100 Temperature Compensation
  • Non-invasive: no pipeline disturbance or pressure loss
  • Easy to install clamp-on sensors with no process interruption
  • All commonly used pipe materials, pipe diameters 3/8" to 118"

 

Please note: Manual data files can be quite large, please be patient while downloading.
The manuals are for information purposes only and shouldn't be used for operating the instrument