Field Mounted Ultrasonic Flowmeter
KATflow 110

  • Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
  • Resolution: 0.025 cm/s (0.05 ft/min)
  • Repeatability: 0.15% of measured value ± 0.01 m/s (2 ft/min)
  • Accuracy:
    Flow velocity: ± 0.5% of measured value
    Volume flow:
    ± 1 to 3% of measured value depending on application
  • Turn down ratio: 1 / 100
  • Outputs: current and digital (pulse)
  • Serial interface RS 485 optional
  • Ultrasound flowmeter in IP66 field enclosure
  • Non-invasive: no pipeline disturbance or pressure loss
  • Easy to install clamp-on sensors with no process interruption
  • All commonly used pipe materials, pipe diameters 1/2" to 100"
  • Measurement is independent of fluid conductivity and pressure

Ultrasonic Flowmeter KATflow 110

   
  Data Sheet KATFlow 110
  Manual KATflow 110
  Measuring Principle KATFlow 110
 

Data Sheet Selection Measuring Point

   
   

 

 

Multi Channel Field Mounted Ultrasonic Flowmeter
KATflow 120

  • Number of channels: 1 to 2
  • Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
  • Resolution: 0.025 cm/s (0.05 ft/min)
  • Repeatability: 0.15% of measured value ± 0.01 m/s (2 ft/min)
  • Accuracy:
    Flow velocity: ± 0.5% of measured value
    Volume flow:
    ± 1 to 3% of measured value depending on application
  • Turn down ratio: 1 / 200
  • Outputs: current, voltage, frequency or digital (pulse)
  • Data logger for 27,000 (optional 100,000) values
  • Serial interface RS232 or RS 485
  • Dual mode ultrasound flowmeter in IP65 field enclosure
  • Non-invasive: no pipeline disturbance or pressure loss
  • Easy to install clamp-on sensors with no process interruption
  • All commonly used pipe materials, pipe diameters 1/2" to 256"
  • Measurement is independent of fluid conductivity and pressure

Ultrasonic Flowmeter KATflow 140

 
  Data Sheet KATFlow 120
  Manual KATFlow 120
  Measuring Principle KATFlow 120
 

Data Sheet Selection Measuring Point

  Data Sheet KATData Software
   

 

 
 

Field Mounted Ultrasonic Flowmeter Hazardous Area
KATflow 160

  • Number of channels: 1or 2
  • Certified: ATEX for Zone 1 & 2
  • Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
  • Resolution: 0.025 cm/s (0.05 ft/min)
  • Repeatability: 0.15% of measured value ± 0.015 m/s
  • Accuracy:
    Flow velocity: ± 0.5% of measured value
    Volume flow:
    ± 1 to 3% of measured value depending on application
  • Turn down ratio: 1 / 100
  • Outputs: current and/or digital (pulse)
  • Serial interface RS 485 optional
  • Dual mode ultrasound flowmeter in IP66 field enclosure
  • Non-invasive: no pipeline disturbance or pressure loss
  • Easy to install clamp-on sensors with no process interruption
  • All commonly used pipe materials, pipe diameters 1/2" to 118"
  • Measurement is independent of fluid conductivity and pressure

Ultrasonic Flowmeter KATflow 160

 
Data Sheet KATFlow 160
Manual KATflow 160
Measuring Principle KATFlow 160

Data Sheet Selection Measuring Point

Data Sheet KATData Software
 
 

 

 