High-End Industrial Humidity / Temperature Transmitter
 High Humidity and Chemical Applications
Series EE32 / EE33

  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +180 °C (-40 to 356 °F)
  • Housing: Metal or Polycarbonate
  • Unique monolithic measuring cell
  • Measurement near condensation (separate T-probe)
  • Purge of chemical contamination
  • Full temperature compensation
  • Pressure tight version up 100 bar (1450 psi)
  • Alarm output and local display optional
  • Interchangeable and remote sensor probe up to 20 m (65 feet)
  • Analogue outputs free selectable and scalable
  • RS 232 interface for configuration
  • Dew point, absolute humidity and other calculated values *)
  • Data output via RS232 serial interface *)
  • RS485 and Ethernet network capability *)
  • Calibrated against NIST traceable factory standards

      *) Series EE33
 

EE22 Humidity / Temperature Transmitter w/ Replaceable Digital Probe

 
  Data Sheet Series EE32 / EE33
  Manual Series EE32 / EE33

Data Sheet Accessories

 

Multifunctional Industrial Humidity / Temperature Transmitter
Humidity / Dewpoint / Wet Bulb / Mixing Ratio......
Series EE29 / EE31

  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +180 °C (-40 to 356 °F)
  • Housing: Metal or Polycarbonate
  • Full temperature compensation
  • Version with 5 mm (0.2 inch) remote probe
  • Pressure tight version up 15 bar (215 psi)
  • Alarm output and local display optional
  • Clean room wall mount version with rear cable entry
  • Interchangeable and remote sensor probe up to 20 m (65 feet)
  • Analogue outputs free selectable and scalable
  • RS 232 interface for configuration
  • Dew point, absolute humidity and other calculated values *)
  • Data output via RS232 serial interface *)
  • RS485 and Ethernet network capability *)
  • Calibrated against NIST traceable factory standards

       *) Series EE31
 

 
  Data Sheet Series EE29 / EE31
  Manual Series EE29/ EE31
Manual Data Logging Software EE31
Calculated Accuracies EE31
RS232 Protocol EE31
Ethernet Protocol EE31

Data Sheet Accessories

 

Economical Industrial Humidity / Temperature Transmitter
Dew and Frost Point Temperature
Series EE23

  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +120 °C (-40 to 248 °F)
  • Housing: Metal or Polycarbonate
  • Dewpoint and frost point temperature calculation
  • 1 %RH accuracy over 0 - 90 %RH optional                                   
  • On site calibration
  • Remote sensor probe up to 20 m (65 feet)
  • Alarm output and local display optional
  • Meteorological version with radiation shield
  • Version with 5 mm (0.2 inch) remote probe
  • Clean room wall mount version with rear cable entry
  • Calibrated against NIST traceable factory standards

EE23 Economical Industrial Humidity / Temperature Transmitter

Data Sheet Series EE23
Manual Series EE23
Data Sheet Accessories

 

Digital Industrial Humidity / Temperature Transmitter
Interchangeable Probes
Series EE
22

  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +80 °C (-40 to 176 °F)
  • Housing: Metal or Polycarbonate
  • Interchangeable probes without recalibration
  • Calibration data stored in sensor probes
  • 1 RH / T probe or 2 separate probes for RH and T
  • 2 %RH accuracy over 0 - 90 %RH
  • On site calibration
  • Remote sensor probe up to 10 m (32 feet)
  • Alarm output and local display optional
  • Clean room wall mount version with rear cable entry
  • Calibrated against NIST traceable factory standards

EE29 General Industrial / Temperature Transmitter

 
Data Sheet Series EE22
Manual Series EE22

Data Sheet Accessories

 

 

Industrial Humidity / Temperature Transmitter
Intrinsically Safe Applications
Series EE
30-EX

  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +180 °C (-40 to 356 °F)
  • Intrinsically Safe version II (1) G [EEx ia] IIC / II 1/2 G EEx ia IIC T6
  • 1 %RH accuracy over 0 - 90 %RH
  • Full temperature compensation
  • RS 232 interface for configuration / monitoring, incl. config. software
  • Analogue outputs free selectable and scalable
  • Dew point, absolute humidity and other calculation functions
  • Pressure tight version up 15 bar (215 psi)
  • Remote sensor probe up to 10 m (32 feet)
  • Optional local display
  • Calibrated against NIST traceable factory standards

EE30-EX Intrinsically Safe Humidity / Temperature Transmitter

   
 
Data Sheet Series EE30-EX
Manual Series EE30-EX
Data Sheet Accessories

Software for EE30-EX

 

Please note: Manual data files can be quite large, please be patience while downloading
The manuals are for information purposes only and shouldn't be used for operating the instrument

             

Phone: 1-215-340-2650
Fax:
    1-215-340-3670
Email:
jlcusa@jlcinternational.com